summaryrefslogtreecommitdiffstats
path: root/tools/guest-diag/semfix_uvmt.py
diff options
context:
space:
mode:
authorArthur Hanson Rasmusson <arthur@vgpu.io>2026-09-29 17:27:48 -0400
committerArthur Hanson Rasmusson <arthur@vgpu.io>2026-09-29 17:27:48 -0400
commitfcb74dfd32442af859ac45979138b40279f96553 (patch)
tree4a761e08eded02f680e5c0ece2e9bf634515f08c /tools/guest-diag/semfix_uvmt.py
parentc903aac3e45a1634764389cd57b7d195b5c895b4 (diff)
downloadopen-iov-fcb74dfd32442af859ac45979138b40279f96553.tar.gz
open-iov-fcb74dfd32442af859ac45979138b40279f96553.zip
guest-diag: stream uvbp pushbuffer kptrs for immediate pinning
The first CE channel's push-buffer was only pinned ~1 minute after the client's failure: uvbp fired at t+4s but semfix's trace read (guest agent, every 5 loops) picked it up at t+70s, so the tracker wait for value 3 spun for 16 s. The guest scanner now emits '#pb 0x<kptr>' from the uvbp trace lines as soon as they appear; the host mirrors them into the sem stream and semfix resolves/pins the push-buffer through the UVM chain on the next loop (sub-second).
Diffstat (limited to 'tools/guest-diag/semfix_uvmt.py')
-rwxr-xr-xtools/guest-diag/semfix_uvmt.py13
1 files changed, 13 insertions, 0 deletions
diff --git a/tools/guest-diag/semfix_uvmt.py b/tools/guest-diag/semfix_uvmt.py
index fd58299..09cc5f8 100755
--- a/tools/guest-diag/semfix_uvmt.py
+++ b/tools/guest-diag/semfix_uvmt.py
@@ -63,6 +63,8 @@ class Stream:
self.off = 0
self.sems = []
self.pids = []
+ self.pbs = []
+ self.new_pbs = []
def poll(self):
try:
@@ -77,6 +79,7 @@ class Stream:
except OSError:
return [], []
new_sems, new_pids = [], []
+ self.new_pbs = []
for line in data.splitlines():
if line.startswith("#sem"):
m = re.search(r"0x([0-9a-fA-F]+)", line)
@@ -85,6 +88,13 @@ class Stream:
if v not in self.sems:
self.sems.append(v)
new_sems.append(v)
+ elif line.startswith("#pb"):
+ m = re.search(r"0x([0-9a-fA-F]+)", line)
+ if m:
+ v = int(m.group(1), 16)
+ if v not in self.pbs:
+ self.pbs.append(v)
+ self.new_pbs.append(v)
elif line.startswith("#pid"):
m = re.search(r"(\d+)", line)
if m:
@@ -265,6 +275,9 @@ def main():
for p in new_pids:
log("stream: client pid %d" % p)
last_pid = p
+ for pb in getattr(stream, "new_pbs", []):
+ log("stream: new pushbuffer 0x%x" % pb)
+ pbs.add(pb)
sems.update(stream.sems)
# The guest-agent trace read is slow under client load; use it only